Previous File Previous Page Single Page Next Page Next File

* 0078-001-H908 (O$XP) DRAWING NO. 41285371-301-02 PAGE 2

0051 * 0052 * THE PROGRAM WILL OPERATE ON AN H316 OR DDP-516 COMPUTER WITH A 0053 * DIGITAL PLOTTER EOM 2113 0054 * 0055 * 0056 * STORAGE 0057 * 0058 * 542 (OCTAL) 0059 * 354 (DECIMAL) 0060 * 0061 * 0062 * USE 0063 * 0064 * PLOT A LINE 0065 * 0066 * CALL O$XP (X,Y,IC) 0067 * 0068 * OR 0069 * 0070 * CALL O$XP PLOT A LINE 0071 * DAC X PEN POSITION, X CO-ORDINATE 0072 * DAC Y PEN POSITION, Y CO-ORDINATE 0073 * DAC IC PEN POSITION INDICATOR 0074 * OCT 0 END OF PARAMETER LIST 0075 * NORMAL RETURN 0076 * 0077 * PLOT IS AN IDENTICAL ENTRY TO O$XP 0078 * 0079 * PROVIDE OFFSET DISTANCES AND SCALE FACTORS 0080 * 0081 * CALL O$XO (XMIN,XFAC,YMIN,YFAC) 0082 * 0083 * OR 0084 * 0085 * CALL O$XO PROVIDE OFFSET DISTANCES AND SCALE FACTORS 0086 * DAC XMIN DISTANCE TO TRANSLATE ORIGIN ALONG X AXIS 0087 * DAC XFAC SCALE VALUE FOR X AXIS 0088 * DAC YMIN DISTANCE TO TRANSLATE ORIGIN ALONG Y AXIS 0089 * DAC YFAC SCALE VALUE FOR Y AXIS 0090 * OCT 0 END OF PARAMETER LIST 0091 * NORMAL RETURN 0092 * 0093 * OFFSET IS AN IDENTICAL ENTRY TO O$XO 0094 * 0095 * PROVIDE THE SCALE VALUE FOR BOTH AXES 0096 * 0097 * CALL O$XF (FACT) 0098 * 0099 * OR 0100 *
Previous File Previous Page Single Page Next Page Next File